The universal transmitters for temperature measurement with resistance thermometers and thermocouples - in a 6-mm housing with infrared interface and SIL approval.

  • Universal usability
    from simple to challenging measurement demands with all known temperature sensors
  • Convenient setting of all parameters
    via IrDA interface. Uncomplicated, menu-guided adjustment also “on site” including archiving of configuration data
  • Intuitive configuration
    of basic parameters – easy, without tools, using 4 rotary and 8 DIP switches
  • Calibrated range selection
    No complicated adjusting
  • Automatic detection
    of the sensor connection (2-, 3- or 4-wire)
  • Protective separation
    according to EN 61140. Protection of maintenance staff and subsequent devices against excessively high voltages up to 300 V AC/DC
  • Functional safety
    up to SIL 2 (up to SIL 3 in case of redundant configuration) with TÜV certificate. Systematically developed according to EN 61508
  • High accuracy
    due to innovative circuit design
  • Minimum space consumption
    in the enclosure - modular housing: just 6 mm wide - more transmitters per meter of DIN rail
  • Low-cost assembly
    Quick mounting, convenient connection of power supply through DIN rail bus connectors (in case of 24 V DC power supply)
  • 5-year warranty

The universal P32100 temperature transmitters provide connection possibilities for all common thermocouples and resistance thermometers. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA port.

3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals. The P32100 offer maximum performance in the smallest of spaces.

Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. All standard thermocouples can be read with internal or external reference junction compensation.

Input voltage signals up to +/- 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt resistors, for example.
Special measuring tasks can be solved with ThermoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.

For applications requiring a high level of functional safety, Knick offers the P32100 transmitter with SIL approval. The requirements of EN 61508 were implemented through specially developed hardware and software. The fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic methods for selective fault detection. The product is SIL 2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL 3 in redundant implementations.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

We look forward to hearing from you!
Contact Us

Technical details

Product Category: Sensor Transmitter
Device Type: Temperature Transmitters
Input: (±)500 mV ... (±)200 V, Resistance Thermometers, Thermocouples, ≤ (±)500 mV
Output: 0 … 10 V, 0 … 20 mA, 4 … 20 mA, ±10 V, ±20 mA
Working Voltage, Min.: 50 V, 300 V
Test Voltage: 2.5 kV, 510 V
Fault Class: 0.1 %, < 0.5 %
Housing: 6 mm Modular housing
Cutoff Frequency: < 1 kHz
Power Supply: 24 V DC
Approvals: CSA, SIL, UL
Product Line: ProLine

Downloads

Manuals

[1433] User Manual (DE, EN, FR)
P32100P0/11-S0003-KTA
Version 04
[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03
[1410] User Manual (DE, EN, FR, BR)
P32100P0/11-KTA
Version 04
[1434] User Manual (DE, EN, FR, BR)
P32100 P0/ ...
Version 03
[1418] User Manual (DE, EN, FR)
P32100P0/11-S0002-KTA
Version 02

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[1401] Data sheet
P32100
Product Description | Specifications | Product Range

Certificates

[11418] Certificate of Compliance (UL)
No. 20181015-E220033 | 2018-OCTOBER-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
P32*00P0/**, A202*0P0..., BL520
[11256] CB Test Certificate
No. DE 2-036775 | 2022-10-11
P32000, P32100, P32200, P32300, A20210, A20220, A20230
[13789] EU Declaration of Conformity (DE, EN, FR)
A20210P0, P32100P0, A20220P0, P32200P0, A20230P0, P32300P0, P32000P0
No. EU231123A | 2023-11-23
[11665] TÜV Rheinland Certificate
No. 968/EZ 272.00/07 | 2007-10-12
Transmitter Series P32*** P0/1
EN 61508 |SlL2, SIL3

Safety guides

[1383] SIL Safety Manual
P32*00P0/1
Version 02

Software

[12155] Paraly SW 111
Parameterization Software
for P32x00 via IrDA Interface

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.