Skip to main content Skip to search Skip to main navigation

P42000 High Voltage Transducer | Input up to ±3600 V | Voltage measurement

Description

P42000 High Voltage Transducer | Input up to ±3600 V | Voltage measurement

Universal high voltage transducers. Input voltages up to Vin = ±3600 V.

  • Universal high voltage transducers
    for converting input voltages up to 3600 V AC/DC to impressed ±20 mA, ±10 V, or 4 ... 20 mA output signals
  • TransShield technology
    enables extremely compact modular housings:
    • Working voltages up to 3600 V AC/DC with a housing width of 67.5 mm
    • Working voltages up to 2200 V AC/DC with a housing width of 45 mm
  • Protection against electric shock
    with protective separation up to 1800 V AC/DC according to EN 61140
  • Test voltages up to 15 kV AC
  • Excellent transmission properties:
    • Gain error < 0.3 %
    • Cutoff frequency 5 kHz (low-pass filter / lower cutoff frequency on request)
    • Rise time T90 approx. 110 µs
  • Maximum accuracy
  • Tremendous flexibility provided by
    • Calibrated switching of up to 16 input/output ranges (working voltage up to 2200 V)
    • Up to 16 customer-specific measuring ranges
    • 20 V to 253 V AC/DC broad-range power supply
  • Reliable function
    even with unstable power supply
  • No damage
    in the case of erroneous power connection
  • Switchable models
    minimize required device variants and save stockkeeping costs
  • Suitable for DC railway systems 
    up to 3000 V DC
  • Mechanically stable
    for operation on ships, rail vehicles and land crafts
  • 5-year warranty

The P42000 isolation amplifiers have been specially conceived for measuring high voltages up to 3600 V (DC). They reliably isolate high potentials at the input circuit.

The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV. Protection against electric shock is achieved through protective separation according to EN 61140 between input and output and power supply.

 

We look forward to hearing from you!
Contact Us

Technical details

Product Category: High Voltage Transducer
Device Type: High Voltage Transducers, Universal Isolated Signal Conditioners
Input: (±)500 mV ... (±)200 V, > (±)200 V
Output: 0 … 10 V, 0 … 20 mA, 4 … 20 mA, Others, ±10 V, ±20 mA
Working Voltage, Min.: 50 V, 300 V, 1000 V, 2000 V, 3600 V
Test Voltage: 2.5 kV, 5 kV, 10 kV, 15 kV, 510 V
Fault Class: < 0.5 %
Housing: 17.5 … 67.5 mm Modular housing
Cutoff Frequency: 5 kHz, < 1 kHz
Power Supply: 24 V AC, 24 V DC, 110 / 115 V AC, 220 / 230 V AC, Broad-range power supply, Others
Approvals: CSA, UL
Product Line: ProLine

Downloads

Manuals

[17375] User Manual
P42000
Version 06

Brochures

[18014] Brochure
Precision Devices
for the Rail Industry
[16310] Brochure
P42000D2
[14160] Brochure
Product Overview Interface Technology

Data Sheets

[1513] Data Sheet
VariTrans P 41000, P 42000 (inkl. D2), P 43000
Product Description | Specifications | Product Range

Certificates

[12429] EU Declaration of Conformity (DE, EN, FR)
P4*000 KTA
No. EU230522A | 2023-12-12
[11463] EU Declaration of Conformity (DE, EN, FR)
Series VariTrans P4x000 (D*-nnnn/D*AG-nnnn/D*TRMS-nnnn)
No. EU221209A | 2023-11-29
[12071] Certificate of Compliance (UL)
P41000, P42000, P43000, P44200, P51000, P52000
MOTOR CONTROLLER ACCESSORIES OVER 1500 VOLTS
No. UL-US-L356768-11-22503102-1 | 202406-28
[14140] Quality Report (MTBF)
Document No. TX180416A
Failure Rate of Series P40000

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

Used in Process or Applications

During battery tests, the charging and discharging operations (battery cycles) are continuously simulated in a HIL (hardware in the loop) configuration that corresponds to the typical use profiles when the electric vehicle is in operation. In the process, a series of parameters are measured, including capacity, battery efficiency, and self-discharging.

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.