Skip to main content Skip to search Skip to main navigation

P44000 Temperature Transmitter | Input Pt100 resistance thermometer (RTD) | High isolation up to 6600V

Description

P44000 Temperature Transmitter | Input Pt100 resistance thermometer (RTD) | High isolation up to 6600V
Precise Temperature Measurement at High Voltage Potentials up to 6 kV
  • Transmitter for Pt100 temperature sensors, 2- or 4-wire connection
  • Fixed range models for 0 to 150 °C, 0 to 200 °C and 0 to 300 °C input ranges
  • Impressed output current of 4 to 20 mA
  • Compact 67.5 and 22.5 mm modular housings based on proven VariTrans technology
  • High isolation up to 6 kV AC/DC basic insulation and up to 2.5 kV AC/DC reinforced insulation with overvoltage category III and pollution degree 2 according to EN 50178 (input against output and power supply)
  • 22.5 mm housing for less demanding isolation requirements up to 2 kV AC/DC (basic insulation)
  • Low measurement error of just ± 1 K (typically ± 0.5 K) and short T90 delay time of 100 ms
  • VariPower broad-range power supply for 20 … 253 V AC/DC ensures safe operation even with unstable power grids
  • Resistant to environmental influences through vacuum encapsulation
  • Suitable for extreme environments: ambient temperature during operation –40 … +85 °C
  • 5-year warranty

When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters are often unsuitable due to their insufficient insulation.

Resistance thermometers can be insulated against high voltage. In practice, however, the available installation space is often too small. Moreover, the insulation is weakened by thermal and mechanical aging.

For temperature measurement on power electronics components, maximum safety is therefore provided by high-voltage resistant galvanic isolation. A typical application is the monitoring of the winding temperature of electric motors, generators or transformers.

The Solution:
Pt100 Transmitter With 6 kV AC/DC Basic Insulation

The new ProLine P 44000 transmitter for high-voltage applications converts the resistance of a 2- or 4-wire Pt100 resistance thermometer into a 4 to 20 mA signal with high accuracy and short delay times.

The output signal is galvanically isolated from the input signal and the voltage supply. The isolation is designed for working voltages of up to 6 kV AC/DC. During routine testing, the test voltage is 15 kV AC. Vacuum encapsulation protects the circuit against environmental influences and ensures that the extraordinary isolation properties are maintained.

The product line covers the standard ranges of 0 to 150 °C, 0 to 200 °C and 0 to 300 °C. The transmitters are available in 67.5 and 22.5 mm modular housings to suit different requirements.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

We look forward to hearing from you!
Contact Us

Technical details

Product Category: High Voltage Transducer, Sensor Transmitter
Device Type: Temperature Transmitters
Input: Resistance Thermometers
Output: 4 … 20 mA
Working Voltage, Min.: 50 V, 300 V, 1000 V, 2000 V, 3600 V, 4800 V, 6600 V
Test Voltage: 2.5 kV, 5 kV, 10 kV, 15 kV, 510 V
Fault Class: < 0.5 %
Housing: 17.5 … 67.5 mm Modular housing
Cutoff Frequency: < 1 kHz
Power Supply: 24 V AC, 24 V DC, 110 / 115 V AC, 220 / 230 V AC, Broad-range power supply
Product Line: ProLine

Downloads

Manuals

[15] User Manual (DE, EN, FR, BR)
P44000
Version 03

Brochures

[18014] Brochure
Precision Devices
for the Rail Industry
[14160] Brochure
Product Overview Interface Technology

Data Sheets

[12258] Data sheet
P44000
Product Description | Specifications | Product Range

Certificates

[12063] EU Declaration of Conformity (DE, EN, FR)
No. EU220125L | 2022-11-25
P44000 (P441**D1-nnnn, P442**D3-nnnn)
[12071] Certificate of Compliance (UL)
P41000, P42000, P43000, P44200, P51000, P52000
MOTOR CONTROLLER ACCESSORIES OVER 1500 VOLTS
No. UL-US-L356768-11-22503102-1 | 202406-28

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.
The electrical measuring technology from Knick provides a range of solutions for signal detection and conversion, current and voltage measurement, and more.

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.