Skip to main content Skip to search Skip to main navigation

SE515 pH Sensor | Memosens | 120 mm | Sigma glass | For water and wastewater treatment

Description

SE515 pH Sensor | Memosens | 120 mm | Sigma glass | For water and wastewater treatment

Reasonably priced sensor for water and wastewater treatment

  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector 
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics
  • Low maintenance, no refilling of electrolyte
  • Integrated temperature detector 
  • Ground-glass sleeve junction
  • Sigma glass; low impedance for low-temperature applications

Thanks to its ground-glass sleeve junction even applicable in heavily contaminated media. Designed for MemoRail applications. High stability and a long life cycle are achieved by the special design.  

Through a ground-glass sleeve junction the reference system is in direct contact with the measured medium. There is hardly any risk of contamination or blocking of the junction. 

Measurement is possible even at low temperatures thanks to a special low-impedance glass. 

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: pH
Connector: Memosens
Explosion protection: non Ex
Length: 120 mm
Process Connection: PG 13.5
Measuring Range: 0 … 14 pH
Temperature: –5 … 80 °C ( 23 ... 176 °F)
Pressure, relative: 0 … 4 bar
Temperature Detector: NTC 30 kΩ
Approvals: KCs
Junction: Ground glass sleeve
Reference System: Ag/AgCl, gel electrolyte
Sensor Material: Low-impedance Sigma glass

Downloads

Manuals

[14165] User Manual | Betriebsanleitung
ZU1054 Sensor Protection | Sensorschutz
Version 01
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[4497] General Instructions (DE, EN, FR, ES, IT)
SE515/1 MS pH Sensor
Version 01

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.

Data Sheets

[2138] Data sheet
SE515 Memosens pH Sensor
Product Description | Specifications | Product Range

Certificates

[12781] EU Declaration of Conformity (DE, EN, FR)
No. EU210706D | 2021-07-06
Memosens Measuring Cable Type CA/MS-...X.., CA/MS-...X..-L
[14511] EU Declaration of Conformity (DE, EN, FR)
No. EU240402B | 2024-04-02
Digital Sensors, non Ex
[11671] EU Declaration of Conformity (DE, EN, FR)
No. EU181113B | 2018-11-13
SE515 Memosens
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00

Our service

Used in Process or Applications

Knick offers innovative process analyzers, high quality holders and fittings, and unique cleaning and calibration systems

Related Products

Skip product gallery
SE554 | Memosens II | Länge: 120 mm | pH
Product number:

SE554X/1-NMSN-B1

SE557 Test Memosens II | Länge 1
Product number:

SE557X/1-NMSN-B1

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.