Skip to main content Skip to search Skip to main navigation

SE565 ORP Sensor | Memosens | 225 mm | Ex | For hygienic processes and sterile applications

Description

SE565 ORP Sensor | Memosens | 225 mm | Ex | For hygienic processes and sterile applications

ORP sensor for hygienic processes and sterile applications.

  • perfect galvanic isolation thanks to Memosens technology
  • no influence of humidity in the connector
  • digital data transfer
  • integrated sensor diagnostics
  • state-of-the-art gel electrolyte
  • integrated temperature detector
  • ceramic junction
  • for hygienic and sterile applications
  • for heavily polluted media
  • for media containing sulfides
  • for media containing proteins
  • suitable for solvent-containing processes

The SE565 ORP sensors are of low maintenance. Through a ceramic junction, the pressurized reference system with gel electrolyte is in contact with the process medium. The measuring electrode is made of platinum.

SE565 sensors are designed for simultaneous measurement of ORP and temperature in industrial processes.

They are suitable for sterilization with steam and they provide a reference system which has been developed for the use in food and pharmaceutical products.

Applications
Hygienic and sterile applications, food and pharmaceutical industry, biotechnology 

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: ORP
Connector: Memosens
Explosion protection: Ex
Length: 225 mm
Process Connection: PG 13.5
Measuring Range: ± 1500 mV
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Approvals: FM, IECEx, JapanEx
Junction: Ceramic (1x)
Reference System: Ag/AgCl, pressurized gel electrolyte
Material of measuring electrode: Platinum

Downloads

Manuals

[17413] User Manual
SE565X/*-NMSN
incl. Ex Approval Japan (JPEx DEK19.0046X)
[2650] User Manual
SE565 Memosens ORP Sensor
Version 03
[14165] User Manual | Betriebsanleitung
ZU1054 Sensor Protection | Sensorschutz
Version 01
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.
[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2645] SE565 Memosens ORP Sensor
Product Description | Specifications | Product Range

Certificates

[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[12781] EU Declaration of Conformity (DE, EN, FR)
No. EU210706D | 2021-07-06
Memosens Measuring Cable Type CA/MS-...X.., CA/MS-...X..-L
[17541] Korean Safety Certificate
Ex ia IIC T3/T4/T6 Ga / 23-KA4BO-0103X
SE565X**-*MS*, SE571X**-MS**
2023-02-21
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…
Reverse osmosis systems are used in a wide range of industrial applications for water treatment. The main application is industrial seawater desalination.
Depending on the sector, industrial wastewater is polluted by heavy metals, grease, oil, alkaline substances or, as in the paper and soap sectors, organic substances that can only be neutralized or separated with great effort.

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.